Sigma Watch is free and independent. If it saves you time, keep it running. ☕ Buy me a coffee
SigmaWatch
CVE coverage

CVE-2026-76820

CVSS 7.7 no coverage
View on NVD →
OpenCTI is an open source platform for managing cyber threat intelligence knowledge and observables. Prior to 7.260701.0, the synchronizerFetch GraphQL query called fetchRemoteStreams after checking only that a remote stream URL used HTTP or HTTPS. The backend did not apply the ingestion deny list or reject private, loopback, and link-local destinations, allowing an authenticated account with the INGESTION capability to make OpenCTI request internal services and cloud metadata endpoints. Returned connection errors could distinguish open HTTP ports, open non-HTTP ports, and closed ports, enabling internal network scanning, while compatible endpoint responses could disclose internal data. This issue is fixed in version 7.260701.0.

Detection rules

No detection found — yet
None of Sigma, Elastic, Splunk ESCU, YARA, Microsoft Sentinel, Snort, or Suricata currently has a rule referencing CVE-2026-76820.